Amine gas treating/Citable Version: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>D. Matt Innis
 
m (Text replacement - "hydrogen sulfide" to "hydrogen sulphide")
 
(9 intermediate revisions by 4 users not shown)
Line 1: Line 1:
#REDIRECT [[Amine gas treating/Draft]]
{{subpages}}
 
'''Amine gas treating''' refers to a group of processes that use aqueous solutions of various [[alkanol]]s (commonly referred to as simply [[amine]]s) to remove [[hydrogen sulphide]] (H<sub>2</sub>S) and [[carbon dioxide]] (CO<sub>2</sub>) from [[gas]]es.<ref name=Kohl>{{cite book|author=Arthur Kohl and Richard Nielson|title=Gas Purification|edition=5th Edition|publisher=Gulf Publishing|year=1997|id=ISBN 0-88415-220-0}}</ref><ref name=Gary>{{cite book|author=Gary, J.H. and Handwerk, G.E.|title=Petroleum Refining Technology and Economics|edition=2nd Edition|publisher=Marcel Dekker, Inc|year=1984|id=ISBN 0-8247-7150-8}}</ref> It is a common process unit used in [[Petroleum refining processes|petroleum refineries]], [[petrochemical]] plants, [[natural gas processing]] plants and other industries. The process is also known as ''[[acid gas]] removal'' and ''gas sweetening''.
 
Processes within petroleum refineries or natural gas processing plants that remove hydrogen sulfide and/or [[mercaptan]]s are commonly referred to as ''sweetening'' processes because they result in products which no longer have the sour, foul odors of mercaptans and hydrogen sulfide.
 
There are many different amines used in gas treating:
 
*[[Monoethanolamine]] (MEA)
*[[Diethanolamine]] (DEA)
*[[Methyldiethanolamine]] (MDEA)
*[[Diisopropylamine]] (DIPA)
*[[Diglycolamine]] (DGA)
 
The most commonly used amines in industrial plants are the [[alkanolamines]] MEA, DEA, and MDEA.
 
Amines are also used in many petroleum refineries to remove [[sour gas]]es from liquid [[hydrocarbon]]s such as [[liquified petroleum gas]] (LPG).
 
==Description of a typical amine treater==
 
Gases containing H<sub>2</sub>S or both H<sub>2</sub>S and CO<sub>2</sub> are commonly referred to as ''[[sour gas]]es'' or ''[[acid gas]]es'' in the hydrocarbon processing industries. The chemistry involved in the amine treating of such gases varies somewhat with the particular amine being used. For one of the more common amines, methanolamine (MEA) denoted as <math>RNH_2</math>, the chemistry may be simply expressed as:
 
:<math>RNH_2 + H_2S \iff RNH_3HS</math>
 
A typical amine gas treating process (as shown in the [[process flow diagram]] below) includes an ''absorber'' unit and a ''regenerator'' unit as well as accessory equipment. In the absorber, the downflowing amine solution absorbs H<sub>2</sub>S and CO<sub>2</sub> from the upflowing sour gas to produce a sweetened gas stream (i.e., an H<sub>2</sub>S-free gas) as a product and an amine solution rich in the [[absorption (chemistry)|absorbed]] acid gases.
 
The resultant ''rich'' amine is then routed into the regenerator (a [[Continuous distillation|distillation]] column called a ''stripper'' with a [[reboiler]]) to produce regenerated or ''lean'' amine that is recycled for reuse in the absorber. The stripped overhead gas from the regenerator is concentrated H<sub>2</sub>S and CO<sub>2</sub>. In petroleum refineries, that stripped gas is mostly H<sub>2</sub>S, much of which often comes from a sulfur-removing process called [[hydrodesulfurization]]. This H<sub>2</sub>S-rich stripped gas stream is then usually routed into a [[Claus process]] to convert it into elemental [[sulphur]]. In fact, the vast majority of the 64,000,000 metric tons of sulfur produced worldwide in 2005 was byproduct sulfur from petroleum refineries, natural gas processing plants and other hydrocarbon processing plants. <ref>[http://minerals.usgs.gov/minerals/pubs/commodity/sulfur/sulfumcs06.pdf Sulfur production report] by the [[United States Geological Survey]]</ref><ref>[http://www.agiweb.org/geotimes/july03/resources.html Discussion of recovered byproduct sulfur]</ref>  In some plants, more than one amine absorber unit may share a common regenerator unit.
 
[[Image:AmineTreating.png|frame|center|380px|{{#ifexist:Template:AmineTreating.png/credit|{{AmineTreating.png/credit}}<br/>|}}Schematic flow diagram of a typical amine gas treating unit used in industrial plants.]]
 
The amine concentration in the absorbent aqueous solution is an important parameter in the design and operation of an amine gas treating process. Depending on which one of the following four amines the unit was designed to use and what gases it was designed to remove, these are some typical amine concentrations, expressed as weight percent of pure amine in the aqueous solution:<ref name=Kohl/>
 
:* Monoethanolamine: About 20 % for removing H<sub>2</sub>S and CO<sub>2</sub>, and about 32 % for removing only CO<sub>2</sub>.
:* Diethanolamine: About 20 to 25 % for removing H<sub>2</sub>S and CO<sub>2</sub>
:* Methyldiethanolamine: About 30 to 55% % for removing H<sub>2</sub>S and CO<sub>2</sub> 
:* Diglycolamine: About 50 % for removing H<sub>2</sub>S and CO<sub>2</sub>
 
The choice of amine concentration in the circulating aqueous solution depends upon a number of factors and may be quite arbitrary. It is usually made simply on the basis of experience. The factors involved include whether the amine unit is treating raw [[natural gas]] or [[Petroleum refining processes|petroleum refinery]] by-product gases that contain relatively low concentrations of both H<sub>2</sub>S and CO<sub>2</sub> or whether the unit is treating gases with a very high percentage of CO<sub>2</sub> such as the offgas from the steam reforming process used in [[ammonia production]] or the [[flue gas]]es from [[Conventional coal-fired power plant|power plants]]. Both H<sub>2</sub>S and CO<sub>2</sub> are acid gases and hence corrosive to [[carbon steel]]. However, in an amine treating unit, CO<sub>2</sub> is the stronger acid of the two. H<sub>2</sub>S forms a film of iron sulfide on the surface of the steel that acts to protect the steel. When treating gases with a very high percentage of CO<sub>2</sub>, corrosion inhibitors are often used and that permits the use of higher concentrations of amine in the circulating solution. Another factor involved in choosing an amine concentration is the  the relative solubility of H<sub>2</sub>S and CO<sub>2</sub> in the selected amine. For more information about selecting the amine concentration, the reader is referred to Kohl and Nielson's book.<ref name=Kohl/>
 
The choice of the type of amine will affect the required circulation rate of amine solution, the energy consumption for the regeneration and the ability to selectively remove either H<sub>2</sub>S alone or CO<sub>2</sub> alone if desired.
 
The current emphasis on removing CO<sub>2</sub> from the flue gases emitted by fossil fuel power plants has led to much interest in using amines for that purpose. ''[Note: For more information on this, see the [[Carbon capture and storage]] article and the section on reducing carbon dioxide emissions in the [[Conventional coal-fired power plant]] article.]'' 
 
In the steam reforming of hydrocarbons such as natural gas or [[petroleum naphtha]] to produce gaseous [[hydrogen]] for subsequent use in the industrial production of ammonia, amine treating is one of the commonly used processes for removing excess by-product carbon dioxide in the final purification of the gaseous hydrogen.
 
== New amine-based materials for gas processing ==
 
In recent years, interest in the development of new materials and technologies for the ''capture'' of carbon dioxide (CO<sub>2</sub>) has increased significantly.  This development appears to be driven largely by increasing concerns about the impact of rising CO<sub>2</sub> emissions on climate change. One outcome has been the introduction of new reactive amines which have chemical structures in which the CO<sub>2</sub>-reactive part of the molecule (the amine group) is tethered to an [[ionic]] ([[salt]]-like) structural element.  The ionic nature of these hybrids makes them less likely to be lost to [[evaporation]] during CO<sub>2</sub> capture operations, and as a result it may be possible to reduce the typical amine loss in scrubbing systems of about 2 [[kilogram|kg]]/[[tonne]] (4 [[U.S. customary units|lb]]/[[U.S. customary units|ton]]) of CO<sub>2</sub> captured.  While systems involving the use of certain simple amine-salt solutions in water were first evaluated for CO<sub>2</sub> capture decades ago, it was only in 2002 <ref>Bates, E. D.; Mayton, R. D.; Ntai, I.; Davis, J. H., Jr., ''CO<sub>2</sub> Capture by a Task-Specific Ionic Liquid'', Journal of the American Chemical Society, 2002, Vol. 124, No. 6, 926-927</ref> that systems of pure, CO<sub>2</sub>-reactive liquid salts (amine-appended ''task-specific ionic liquids'' called TSILs) were first introduced.  Recently, the researchers responsible for that development have reported improved approaches<ref>Soutullo, M. D.; Odom, C. I.; Wicker, B. F.; Henderson, C. N.; Stenson, A. C.; Davis, J. H., Jr., ''Reversible CO<sub>2</sub> Capture by Unexpected Plastic-, Resin, and Gel-like Ionic Soft Materials Discovered During the Combi-Click Generation of a TSIL Library'', Chemistry of Materials, 2007, Vol. 19, No. 15, 3581-3583</ref> (e.g., the use of [[Click chemistry]] and commodity chemicals) for the preparation of CO<sub>2</sub>-reactive salts, procedures which result in salts that are much less expensive to prepare than the earlier first-generation of materials.  Interestingly, the library of new compounds obtained in this fashion also included CO<sub>2</sub>-reactive salts that are plastic-, resin- and gel-like in character.
 
==References==
{{Reflist}}

Latest revision as of 09:37, 6 March 2024

This article has a Citable Version.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This version approved by two Editors (first and second) from at least one of the listed workgroups. The Engineering and Chemistry Workgroups are responsible for this citable version. While we have done conscientious work, we cannot guarantee that this version is wholly free of mistakes. See here (not History) for authorship.
Help improve this work further on the editable Main Article!

Amine gas treating refers to a group of processes that use aqueous solutions of various alkanols (commonly referred to as simply amines) to remove hydrogen sulphide (H2S) and carbon dioxide (CO2) from gases.[1][2] It is a common process unit used in petroleum refineries, petrochemical plants, natural gas processing plants and other industries. The process is also known as acid gas removal and gas sweetening.

Processes within petroleum refineries or natural gas processing plants that remove hydrogen sulfide and/or mercaptans are commonly referred to as sweetening processes because they result in products which no longer have the sour, foul odors of mercaptans and hydrogen sulfide.

There are many different amines used in gas treating:

The most commonly used amines in industrial plants are the alkanolamines MEA, DEA, and MDEA.

Amines are also used in many petroleum refineries to remove sour gases from liquid hydrocarbons such as liquified petroleum gas (LPG).

Description of a typical amine treater

Gases containing H2S or both H2S and CO2 are commonly referred to as sour gases or acid gases in the hydrocarbon processing industries. The chemistry involved in the amine treating of such gases varies somewhat with the particular amine being used. For one of the more common amines, methanolamine (MEA) denoted as , the chemistry may be simply expressed as:

A typical amine gas treating process (as shown in the process flow diagram below) includes an absorber unit and a regenerator unit as well as accessory equipment. In the absorber, the downflowing amine solution absorbs H2S and CO2 from the upflowing sour gas to produce a sweetened gas stream (i.e., an H2S-free gas) as a product and an amine solution rich in the absorbed acid gases.

The resultant rich amine is then routed into the regenerator (a distillation column called a stripper with a reboiler) to produce regenerated or lean amine that is recycled for reuse in the absorber. The stripped overhead gas from the regenerator is concentrated H2S and CO2. In petroleum refineries, that stripped gas is mostly H2S, much of which often comes from a sulfur-removing process called hydrodesulfurization. This H2S-rich stripped gas stream is then usually routed into a Claus process to convert it into elemental sulphur. In fact, the vast majority of the 64,000,000 metric tons of sulfur produced worldwide in 2005 was byproduct sulfur from petroleum refineries, natural gas processing plants and other hydrocarbon processing plants. [3][4] In some plants, more than one amine absorber unit may share a common regenerator unit.

(GNU) Image: Milton Beychok
Schematic flow diagram of a typical amine gas treating unit used in industrial plants.

The amine concentration in the absorbent aqueous solution is an important parameter in the design and operation of an amine gas treating process. Depending on which one of the following four amines the unit was designed to use and what gases it was designed to remove, these are some typical amine concentrations, expressed as weight percent of pure amine in the aqueous solution:[1]

  • Monoethanolamine: About 20 % for removing H2S and CO2, and about 32 % for removing only CO2.
  • Diethanolamine: About 20 to 25 % for removing H2S and CO2
  • Methyldiethanolamine: About 30 to 55% % for removing H2S and CO2
  • Diglycolamine: About 50 % for removing H2S and CO2

The choice of amine concentration in the circulating aqueous solution depends upon a number of factors and may be quite arbitrary. It is usually made simply on the basis of experience. The factors involved include whether the amine unit is treating raw natural gas or petroleum refinery by-product gases that contain relatively low concentrations of both H2S and CO2 or whether the unit is treating gases with a very high percentage of CO2 such as the offgas from the steam reforming process used in ammonia production or the flue gases from power plants. Both H2S and CO2 are acid gases and hence corrosive to carbon steel. However, in an amine treating unit, CO2 is the stronger acid of the two. H2S forms a film of iron sulfide on the surface of the steel that acts to protect the steel. When treating gases with a very high percentage of CO2, corrosion inhibitors are often used and that permits the use of higher concentrations of amine in the circulating solution. Another factor involved in choosing an amine concentration is the the relative solubility of H2S and CO2 in the selected amine. For more information about selecting the amine concentration, the reader is referred to Kohl and Nielson's book.[1]

The choice of the type of amine will affect the required circulation rate of amine solution, the energy consumption for the regeneration and the ability to selectively remove either H2S alone or CO2 alone if desired.

The current emphasis on removing CO2 from the flue gases emitted by fossil fuel power plants has led to much interest in using amines for that purpose. [Note: For more information on this, see the Carbon capture and storage article and the section on reducing carbon dioxide emissions in the Conventional coal-fired power plant article.]

In the steam reforming of hydrocarbons such as natural gas or petroleum naphtha to produce gaseous hydrogen for subsequent use in the industrial production of ammonia, amine treating is one of the commonly used processes for removing excess by-product carbon dioxide in the final purification of the gaseous hydrogen.

New amine-based materials for gas processing

In recent years, interest in the development of new materials and technologies for the capture of carbon dioxide (CO2) has increased significantly. This development appears to be driven largely by increasing concerns about the impact of rising CO2 emissions on climate change. One outcome has been the introduction of new reactive amines which have chemical structures in which the CO2-reactive part of the molecule (the amine group) is tethered to an ionic (salt-like) structural element. The ionic nature of these hybrids makes them less likely to be lost to evaporation during CO2 capture operations, and as a result it may be possible to reduce the typical amine loss in scrubbing systems of about 2 kg/tonne (4 lb/ton) of CO2 captured. While systems involving the use of certain simple amine-salt solutions in water were first evaluated for CO2 capture decades ago, it was only in 2002 [5] that systems of pure, CO2-reactive liquid salts (amine-appended task-specific ionic liquids called TSILs) were first introduced. Recently, the researchers responsible for that development have reported improved approaches[6] (e.g., the use of Click chemistry and commodity chemicals) for the preparation of CO2-reactive salts, procedures which result in salts that are much less expensive to prepare than the earlier first-generation of materials. Interestingly, the library of new compounds obtained in this fashion also included CO2-reactive salts that are plastic-, resin- and gel-like in character.

References

  1. 1.0 1.1 1.2 Arthur Kohl and Richard Nielson (1997). Gas Purification, 5th Edition. Gulf Publishing. ISBN 0-88415-220-0. 
  2. Gary, J.H. and Handwerk, G.E. (1984). Petroleum Refining Technology and Economics, 2nd Edition. Marcel Dekker, Inc. ISBN 0-8247-7150-8. 
  3. Sulfur production report by the United States Geological Survey
  4. Discussion of recovered byproduct sulfur
  5. Bates, E. D.; Mayton, R. D.; Ntai, I.; Davis, J. H., Jr., CO2 Capture by a Task-Specific Ionic Liquid, Journal of the American Chemical Society, 2002, Vol. 124, No. 6, 926-927
  6. Soutullo, M. D.; Odom, C. I.; Wicker, B. F.; Henderson, C. N.; Stenson, A. C.; Davis, J. H., Jr., Reversible CO2 Capture by Unexpected Plastic-, Resin, and Gel-like Ionic Soft Materials Discovered During the Combi-Click Generation of a TSIL Library, Chemistry of Materials, 2007, Vol. 19, No. 15, 3581-3583